Genuine OEM by default Island-Wide Delivery WhatsApp Support

Car AC Expansion Valve and Orifice Tube Repair

Quick answer The expansion valve meters liquid refrigerant into the evaporator, and some systems use a fixed orifice instead. A stuck, dirty or frozen valve gives weak or fluctuating cooling, ice on the evaporator, or a buzz inside the cabin. The gauges tell you which, because each failure leaves its own pressure pattern. A gas refill will not free a stuck valve.
Position
Directly upstream of the evaporator, between the high and low pressure sides, per VW SSP 208
What controls it
Refrigerant temperature at the evaporator outlet
Orifice tube
Fixed calibrated bore, with a collecting tank on the low side, per VW SSP 208
Flushing
Cannot be flushed. Adapters bridge it during a flush, per HELLA
Drier capacity
6 to 12 g of water, per VW SSP 208. Past that, water reaches the valve

Two designs, one job

DesignHow it worksWhat goes with it
Expansion valve (TXV)A thermal head reads the temperature at the evaporator outlet and opens or closes a small valve to match.A fluid container with drier on the high-pressure side.
Orifice tube (VW calls it a restrictor)A fixed calibrated bore, with a dirt strainer before it and an atomising strainer after it.A collecting tank on the low-pressure side, which also keeps liquid out of the compressor.

An orifice tube has an arrow that must point to the evaporator. Your car's workshop manual shows which design it uses. Our catalogue lists the part as AC Expansion Valve.

What each failure looks like on the gauges

These valve lines come from HELLA's tables, which it calls a guide only. The full table is on AC diagnostics.

PressuresVent airWhat it can mean
Low side normal to occasionally low, high side occasionally highWarmer, may fluctuateValve stuck, closing at times
Low side high, high side lowWarmer, near outside temperatureValve stuck open, or a compressor fault
Both sides fluctuatingFluctuatingValve or compressor fault
Orifice system: low side normal, high side normal to highFluctuatingMoisture, orifice blocking at times
Orifice system: low side high, high side normalWarmerOrifice defective

What kills a valve

  • Moisture. VW says a saturated drier lets water reach the valve nozzle, where it freezes and cuts cooling.
  • Metal from a failing compressor. HELLA says wear particles clog valves and orifice tubes.
  • Dissolved plastic. VW says refrigerant can dissolve some plastics, which settle in the valve as they cool.
  • Rubber particles. HELLA lists these too.

HELLA says a contaminated valve can buzz, whistle or drone loud enough to hear in the cabin, and that too much flow can ice the evaporator or strain the compressor. A new valve in a dirty or wet circuit meets the same end, so fix the source too.

New valve with every compressor job?

HELLA says to replace the valve after a flush, and to renew it with a compressor or evaporator. VW's current 87-18-02 replaces it with the compressor on the 2015-17 Golf (US). VW's earlier 2015 revision let it go back in, and that note is gone. See compressor replacement.

Fitting rules that decide whether it works

  • Leave the setting alone. VW says valve settings may not be altered, and HELLA says never to change the factory adjusting screw.
  • Keep the thermal insulation. VW says fitting without it changes how the valve controls.
  • Do not bend the sensor line on valves that have one. It holds a special gas.
  • Use new O-rings suited to the refrigerant, greased with refrigerant oil, and two wrenches on each joint, per HELLA.
  • Fit a new drier, pull a vacuum and charge by weight.

Book an AC diagnosis

Tell us the vehicle and the refrigerant on the under-bonnet label when you book. We confirm which workshop can take the job before you bring the car. Bring the fault codes if you have them.

Parts involved

Quoted to order. We confirm fitment from your VIN before you order.

Questions owners ask

Can an expansion valve be cleaned?

HELLA says it cannot be flushed. During a flush, an adapter bridges it, and the valve is replaced afterwards.

Does a bad valve damage the compressor?

It can. HELLA says incorrect flow can overload the compressor. VW adds that liquid refrigerant cannot be compressed and would destroy it.

Why does my AC go cold, then warm, then cold?

Water freezing at the valve is one cause. Ice on the evaporator and a sensor cut-out are others. Our page on an AC that turns on and off covers the differences.

Will a gas refill help a stuck valve?

No. HELLA also warns against overfilling while diagnosing, because too much refrigerant gives high pressures of its own. Read the gauges before anything goes in.

Related

Sources

Last updated 31 October 2026.